Independently verified

Tested at an accredited fall protection laboratory

Gravitec Systems evaluated the Epic ERA Shield using test methods derived from the ANSI/ASSP Z359 fall protection standards. Under controlled drop conditions, the Shield detected the fall.

PASS

Result

Fall detection

This testing is described as third-party validation. It is not presented as regulatory certification, approval, endorsement, or a guarantee by Gravitec Systems.

Laboratory
Gravitec Systems Inc.
Accreditation
ISO 17025 accredited test facility
Test method
Derived from ANSI/ASSP Z359
Conditions
Controlled drop, ambient dry
Location
Poulsbo, Washington

Test results

Ambient dry, Gravitec Systems Inc.

MeasurementAcceptance criteriaResultPass / failExp. uncertainty
Fall detectionFall detectedVerifiedPASS–
Maximum arrest forceInformation only1,194.2 lbf–±6.2
Average arrest forceInformation only860.8 lbf–±6.1
Deployment distanceInformation only36.4 in–±0.2

Scroll sideways to see all columns

Arrest force and deployment distance describe the fall-arrest equipment used in the drop. They are recorded for information and are not measures of the Shield itself.

Gravitec Systems Inc. is an independent fall protection testing laboratory in Poulsbo, Washington, operating an ISO 17025 accredited test facility.

Evaluation in a professional fall-protection environment

Testing was conducted in a professional fall-protection environment using controlled test conditions and specialized equipment.

This important milestone supports EGI’s commitment to independently evaluated performance, responsible product development, and advancing technology designed to strengthen worker safety and emergency response.

Controlled testing conducted at the Gravitec Systems fall-protection training and testing facility.
Controlled testing conducted at the Gravitec Systems fall-protection training and testing facility.

September 18, 2026 — Gravitec Systems validation testing

  1. Milestone 1: Controlled testing conducted

    The Epic ERA Shield was evaluated under controlled test conditions in a professional fall-protection environment.

  2. Milestone 2: Specialized equipment used

    Testing activity was conducted at the Gravitec Systems fall-protection training and testing facility using specialized equipment.

  3. Milestone 3: Validation milestone completed

    Third-party validation testing was completed as part of the continued development and evaluation of the Epic ERA Shield.

Epic Global Innovations representatives following third-party validation testing at Gravitec Systems.
Epic Global Innovations representatives following third-party validation testing at Gravitec Systems.