Epic ERA Shield Test summary

← Back to the site

Independently verified

Tested at an accredited fall protection laboratory

Gravitec Systems evaluated the Epic ERA Shield using test methods derived from the ANSI/ASSP Z359 fall protection standards. Under controlled drop conditions, the Shield detected the fall.

Gravitec Systems Inc., ISO 17025 accredited testing laboratory, Poulsbo, Washington

Load versus time

From the drop test. Ambient dry conditions.

0 200 400 600 800 1000 1200 1400 0 500 1000 1500 2000 2500 3000 TIME (ms) LOAD (lbf) 1,194.2 lbf peak

Test results

Ambient dry, Gravitec Systems Inc.

MeasurementAcceptance criteriaResultPass / failExp. uncertainty
Fall detectionFall detectedVerifiedPASS–
Maximum arrest forceInformation only1,194.2 lbf–±6.2
Average arrest forceInformation only860.8 lbf–±6.1
Deployment distanceInformation only36.4 in–±0.2

Scroll sideways to see all columns

Arrest force and deployment distance describe the fall-arrest equipment used in the drop. They are recorded for information and are not measures of the Shield itself.

Gravitec Systems Inc. is an independent fall protection testing laboratory in Poulsbo, Washington, operating an ISO 17025 accredited test facility.